EasySieve pro / EasySieve pharma 技术参数
| System requirements: | Windows 11 or higher |
|---|---|
| Computer: | IBM compatible PC |
| CPU: | 1.6 GHz or more, Multicore (recommended Intel i7 or comparable) |
| RAM: | 4 GB minimum (8 GB recommended) |
| Connections: | min. 2 x USB 2.0 (sieving machine, balance) |
| HDD: | 256 GB |
| Display resolution: | 1920 x 1080 |
| Graphical User Interface, guided sieving: | Yes |
| Languages: | German and English |
| Parameter units changeable: | size in mm/µm/mesh/inch mass in g/kg time in s/min |
| SOPs: | Yes, integrated in methods |
| Individual sample labelling: | Yes, for each sample, reference to method during data choice and in overview |
| Parameter setting per test sieve: | Yes |
| LIMS ready: | yes |
| Teamviewer online support: | Yes |
| Screenshot function: | yes |
| Back-up function: | Yes |
| Automatic storage of results: | Yes |
| Results shown, as table or graphs: | Yes |
| Data export: | Yes: *.xls, *.xlsx, *.xps, *.csv, *.pdf, *.png, *.jpg, *.txt, *.rtf, *.html, *.mht |
| Different diagram types (linear or logar.): | Yes, log/lin, log/log, lin/lin for x and y axis |
| Different diagram types: | Cumulative, RRSB, Histogram, density, residual distribution |
| Calculation of individual dx values: | More than 10 |
| Label naming: | ISO (q3/Q3/1-Q3/p3) or descriptive (density/total distribution/residual distribution/percent) |
| Overlay of results: | Yes, up to 32 Curves, tables and overview |
| Individual scalable diagrams: | Yes, via zoom in or via setting of max. axis value |
| Highest precision thanks to: | Sieve-Check function, Weighing-Assistant and Weigh-in tolerance, Filter function for sieve rows, TrendAnalysis for sieves and methods, Backweighing-Tolerance |
| Connection to sieving machines: | Yes, AS 200 control B (USB, from year of manufacture 2016), AS 200 jet (USB), AS 200 tap (RS232), AS 300 control B (USB, from year of manufacture 2016), AS 400 control (RS232), AS 450 control (RS232) |
| Connection of external balance: | Yes, RS232-communication via USB |
| Standard balance driver: | Yes, scale management for external scales, communication protocols for specific scales Kern, Sartorius, Mettler are stored. |
附加功能 EasySieve pharma 技术参数
| Software validation: | ISPE GAMP 5, EC GMP Annex 11 conform, AuditTrail acc. to FDA 21 CFR part 11 |
|---|---|
| User management: | Yes, free configurable levels, individual rights option for each user |
| Role and password management: | Yes |
| Audit-trail with E-signature: | Yes |
| Enforce audit trail comments: | yes |
| Generation/Export of user lists and daily reports: | Yes |
| Restore: | Yes |
分析筛分软件EasySieve / EasySieve CFR 资料下载
Product data sheet Easy Sieve
下载
pdf 英语 (~1 MB)
pdf 保加利亚语 (~1 MB)
pdf 日文 (~1 MB)
pdf 西班牙语 (~1 MB)
pdf 捷克语 (~1 MB)
pdf 俄语 (~1 MB)
pdf 荷兰语 (~1 MB)
pdf 德语 (~1 MB)
pdf 葡萄牙语 (~1 MB)
pdf 中文 (~2 MB)
pdf 挪威语 (~1 MB)
pdf 匈牙利 (~1 MB)
pdf 朝鲜语 (~1 MB)
pdf 意大利语 (~1 MB)
pdf 罗马尼亚语 (~1 MB)
pdf 法语 (~1 MB)
pdf 土耳其 (~1 MB)
pdf 波兰语 (~1 MB)
pdf 斯洛伐克 (~1 MB)
1
您的查询无任何查询结果